PDU Full Form Name
Full Form of PDU:
Protocol Data Unit
PDU Full Form is Protocol
Data Unit. A protocol data unit (PDU) is an OSI (open-system
interconnection) it is used in telecommunications. The term refers to a group
of information either added or removed by an open system interconnection layer.
Each layer uses the PDU to communicate and exchange information; the
information can be read by the other layer on the receiving device and can be
handed over to next layer after stripping. A protocol data unit delivers
information in the form of unit among peer entities of networks that contain
control information such as user data, address information etc.
PDU represents a unit of data
that is specified in the protocol of a given layer in a layered system
consisting user data as well as protocol control information. PDU is an
important term related to the four layers of the OSI model. Layer 1, PDU
is a bit (symbol), Layer 2 it is a frame, Layer 3 it is a packet and Layer 4 it
is a segment. PDU has four fields; (1) Source service access point, (2) The
destination services access point, (3) Information field& (4) Control
field.
PDU is the structured information
that is passed to a matching protocol layer that allows the layer to deliver
its function or service efficiently. When PDU passes over from the layer that
constructed it to the layer that only delivers it becomes a service data unit
to that layer. A single-letter prefix is added to PDU to understand different
layers (i.e.,LPDU – for the data link layer, NPDU for the network layer&
TPDU for the transport layer).
PDU Full Form – Power Distribution Unit
Full Form of PDU stands
for Power Distribution Unit. A power distribution unit
or commonly termed as mains distribution unit is an equipment fixed with a
number of outputs that are designed to distribute electric power to
various electronic resources. This includes series of computers, servers and
networking equipment within a data center.
A data center has to face several
problems when it comes to safeguard power management. Hence, data centers
depend upon PDU monitoring to maximize the uptime, improve the efficiency and
scale the growth. PDU works as a central unit that controls and distributes
electric power evenly in a data center.It has multiple sources of integrated
power outputs. Each power output is connected to a data center, server or
network directly.
The basic PDU is designed for
standard outlets with no monitoring and remote control access. The
rack-mounted & floor-mounted PDUs are more reliable and sophisticated &
provide data to calculate PUCE (Power Usage Effectiveness). A PDU can manage
and distribute larger amounts of energy as compared to a normal power strip and
accordingly provides electrical power to multiple equipment racks. A
rack-mountable PDU mounts directly to the rack and controls as well as monitors
power to specific network servers and other devices in the data center.
It also helps in maintaining a
balanced power supper thereby increasing the life of the equipment. A
floor-mounted PDU provides an important management bridge between the source of
power and various equipment racks within network operations center (NOC) or a
data center. PDUs can be controlled and accessed over the network. PDUs with
multiple functions like power filtering, load balancing, and remote monitoring,
etc. that improves the quality of power supply are available in the market.